Cooling Everywhere.

Stable temperature and humidity respecting ASHRAE standards

To guarantee a safe environment for your servers, Etix Everywhere provide the most stable temperature and humidity range in all of its sites. Our engagement respects the ASHREA standards.

MOST STABLE COOLING SOLUTION FOR YOUR SERVERS

Temperature range between 18°C to 27°C, humidity range between 20% and 80%.

Intelligent and adaptive cooling technology to reduce power usage

PUE < 1.4

in most of our sites

18 to 27°C

in the cold aisled

WUE < 0,01

L/kWh

Recovery

waste heat

Our cooling's highlights

Etix Everywhere apply the latest design innovation in the cooling design development in each of its site. This guarantees 100% uptime while optimizing the PUE and reducing carbon footprint.

Best PUE & WUE trade-off
Data center environmental impact must be estimated not just with the electricity consumed but also with the water used in the cooling system. Etix Everywhere has always calculated the best trade-off ratio between PUE and WUE in all of its data centers.

Compliant with ASHRAE 90.4

ASHRAE 90.4 is a new standard that is designed to help data centers effectively monitor temperature and humidity levels so that downtime is reduced, and enhanced efficiencies can be introduced. This standard focuses on the use of on-site and off-site renewable energy. It uses both Mechanical Load and Electrical Loss to better determine the maximum allowable values per climate zones. 

ASHRAE standards impose a very precise number and position of sensors per rack together with a precise monitoring tool which could further dictate the most effective air flow containment strategies for each aisle.

Our sustainable initiatives

As a member of the Climate Neutral Data Center Pact, Etix Everywhere is committed to reduce its carbon footprint.

Free cooling solution
In order to reduce the usage of cooling compressor and thus the electricity consumption, Etix Everyhwere install Free Cooling solutions to use the outside cold air available (at night or in winter) to cool down the server room.
Closed loop water system
Etix Everywhere has always rejected adiabatic cooling technology that is a huge water consumer. Instead, Etix Everywhere is using closed loop water cooling system that allow to have the best WUE available on the market.
Sensors & auto-compressor
To avoid having cooling equipment working continiously but instead having it working only when necessary, Etix Everywhere install in each of its data center temperature sensors & automatic compressors connected.
Waste heat recovery
Etix Everywhere deploys wast heat recovery solutions in its data centers. The cities or nearby industries can benefit from waste heat generated by servers being turned into thermal energy in their heating systems
Previous slide
Next slide

Popular Questions About Cooling

We combined every popular questions about our Data center cooling

According to ANSI/ASHRAE Standard 90.4-2019, the maximum temperature for a server room should never go beyond 27 degrees Celcius.

According to Uptime Institute, the average data center’s PUE is 1.58 as of 2020. Etix Everywhere data center PUE are lower than 1.4.

Data center are large producers of heat due to servers, this waste heat can be reinjected in local metropolitan heat network or directly connected to industry using electricty for heating.